Access control systems help regulate the flow of traffic and enforce local occupancy rules
Pre-Requisites:
1. Navori QL Server and Player must be running version 2.2.5
2. Must have an Intel CPU or alternatively using the Intel Computing Node, Windows 10 PC, minimum specs Intel Core i5 with 4GB RAM.
3. Player License MUST have the Access Control Add-On.
4. USB Camera 1080p/2160p or IP Camera 1080p RTSP - minimum 10 fps
5. Further details, please refer to the technical requirements sheet
How to Install QL Player for Windows with Access Control.
1.Follow the QL Player for Windows setup guide as per in faq.
If the player license you have selected for the installation has the Access Control Add on, you will notice a command window installing the configuration files for Access Control during the installation.
2. Once the software has been successfully installed and the player has rebooted you will see the following ICON on your desktop.
Aquaji Settings
3. Double Click to Launch the Aquaji Settings and you will be brought to the Access Control configuration Settings webpage.
Note: Please make sure you're opening the Aquaji Settings in Google Chrome or any other browser except for Internet Explorer.
Please Note: the local URL for the Access Control Configuration Settings are:
However, you can access the player's Access Control Configuration settings from any PC by using the player's IP address followed by :4000
Reminder: You will need to be on the same domain to access your IP Address.
4. If you're accessing the Access Control Configuration settings locally on the PC, you will not be prompted to enter credentials however if you're accessing from the IP address, you will be prompted to log in.
Enter your QL Manager Username
Enter your QL Manager Password
Press Sign In.
5. Upon logging in, you will see the QL Server URL Player Serial Number and a live view of your USB camera. You can stop and resume the live view anytime by pressing the "stop" and "play" buttons.
6. Important Configuration Steps:
SOURCE
Source Type: If you are using a USB Camera select WebCam
USB Camera: 0 refers to the first or default USB camera connected to your PC. If you have more than 1 camera such as a built-in laptop camera which is normally the default then select 1. If this is the only camera leave the value at 0.
Source Type: Video_Steam (Camera coming from an external source)
Stream RTSP: Enter the URL of your RTSP video stream
Inbound People Direction: Select the path people entering the premises are expected to take. For example, if people will be walking from the right of the camera view to the left to enter the location, then select right_to_left. People taking the opposite path will be counted as leaving instead of entering.
RESOLUTION
Enter the width and height of the resolution at which you want to analyze your stream. The minimum is FULL HD 1920 x 1080 and Maximum based on the Camera's max resolution.
MASK
You can mask certain areas so that the camera is only analyzing a portion of the view such as the entrance or exit. This allows you to ignore portions of the camera view you don't want Access Control to act upon.
Please Note: -1 for all settings below is the default setting for full screen, Access Control will analyze the entire camera view.
EG:
Mask Preview:
7. Once the Access Control Configuration is complete, press the Save button to save your settings.
How to configure Access Control from QL Manager (Navori CMS)
Important Information:
1. For the moment, Navori playback of Access Control-based triggered media and feeds is available on Windows and Android ONLY.
2. You may add additional Access Control cameras to the same group and they will all share the same Access Control feed.
3. Access control feed and group settings will only become available after the activation of a player with the Access Control add-on in its license.
Step 1 - Setup Maximum Occupancy
1. Double click on the group containing the Players, eg: NA Access Control. You will be prompted to enter the Maximum Occupancy allowed in the premise.
Note: You may offset the number of employees into the maximum occupancy if they enter through an unmonitored entrance.
Number of People / RESET:
The number of people can be modified for certain scenarios such as:
-Employees entering from an unmonitored back door
-One of your cameras has stopped or is under maintenance.
If you modify the number of people and press RESET(saves the change), the change will reset the number of people in the feed to the new value entered and continue the count from there, the change will be reflected immediately in the Access Control feed and player.
Step 2 - Where to access the Access Control Feed?
1.The *AccessControl feed can be accessed through;
Template Designer > DATA FEED MANAGER or,
Any media via PLAY IF / CONDITIONAL TRIGGERING DATA FEED MANAGER
EG: In this example, we have created a Template that uses the RemainingPlaces column from the *AccessControl feed. The data will be updated live.
Step 3 - Ways to Utilize the *AccessControl feed.
You may use the *AccessControl feed in various different ways such as scenario-based playback using the Navori PLAY IF or CONDITIONAL TRIGGERING feature.
PLAY IF
(Media or Template with rule-based condition(s) added into a playlist and scheduling grid)
CONDITIONAL TRIGGERING
(Media or Template added to the Published Trigger Folder, overrides the existing playlist if the condition(s) are met and returns to playback when conditions are no longer met)